Southern Pacific classes AC-4, AC-5 and AC-6
After the Southern Pacific had already rebuilt several Cab Forward 2-8-8-2 Mallets into simple articulated, the 1928 AC-4 was the first class to be built as a simple expansion Cab Forward from the start. Superintendent George McCormick was responsible and production took place at Baldwin. Like the AC-1 to AC-3, the AC-4 also had four cylinders of the same size without compound working. Thanks to a two-axle leading bogie, a larger firebox could now be accommodated. The delivery of oil to the front of the locomotive was ensured using the proven system with an overpressure of 5 psi.
The AC-4's valve gear had a limited cutoff, which initially reduced the starting tractive effort somewhat and was later removed. After ten AC-4, 16 AC-5 were built, which were slightly heavier. The 25 AC-6, which also had a higher boiler pressure and a smaller superheater, were once again significantly heavier. They received a new, cast frame in 1947 and 1948, which further increased the weight. All three classes were retired between 1953 and 1956.
Technical data
General
| Property | AC-4, AC-5 | AC-5 | AC-6 |
|---|---|---|---|
| Built | 1928 | 1929 | 1930 |
| Manufacturers | Baldwin | ||
| Wheel arrangement | 4-8-8-2 | ||
| Gauge | 1,435 mm (Standard gauge) | ||
Dimensions and weights
| Property | AC-4, AC-5 | AC-5 | AC-6 |
|---|---|---|---|
| Length loco | 23.76 m | ||
| Wheelbase | 20.37 m | 20.50 m | |
| Total wheelbase | 32.44 m | 32.60 m | |
| Service mass | 278.8 t | 282.4 t | 290.1 t |
| Adhesion mass | 215.5 t | 218.9 t | 234.5 t |
| Total mass | 397.2 t | 400.8 t | 408.5 t |
| Rigid wheelbase | 5.16 m | ||
| Axle load | 27.4 t | 28.1 t | 31.3 t |
| Water capacity | 61,142 l | ||
| Fuel capacity | 18,594 l (oil) | ||
Boiler
| Property | AC-4, AC-5 | AC-5 | AC-6 |
|---|---|---|---|
| Grate area | 12.914 m² | ||
| Firebox surface | 47.659 m² | ||
| Tube heating surface | 604.521 m² | 553.61 m² | |
| Evaporative heating surface | 652.18 m² | 601.269 m² | |
| Superheater surface | 277.687 m² | 254.183 m² | |
| Total heating surface | 929.9 m² | 855.5 m² | |
Power plant
| Property | AC-4, AC-5 | AC-5 | AC-6 |
|---|---|---|---|
| Driver diameter | 1,613 mm | ||
| Boiler pressure | 16.2 bar | 17.2 bar | |
| Expansion type | simple expansion | ||
| Cylinders | four, 610 x 813 mm | ||
Power
| Property | AC-4, AC-5 | AC-5 | AC-6 |
|---|---|---|---|
| Power source | steam | ||
| Indicated power | 4,206 kW (5,719 PS) | 4,474 kW (6,083 PS) | |
| Starting effort | 515.8 kN | 548.8 kN | |
Calculated values
| Property | AC-4, AC-5 | AC-5 | AC-6 |
|---|---|---|---|
| Factor of adhesion | 1 : 4.10 | 1 : 4.16 | 1 : 4.19 |
| Optimal speed | 50 km/h | ||
| Power-to-weight ratio | 15.1 kW/t | 14.9 kW/t | 15.4 kW/t |
| Heating Surface Equivalent | 1,445.8 m² | 1,347.9 m² | |
| Cylinder volume/HSE | 1 : 656.30 | 1 : 703.97 | |
| Adhesive weight/Total | 1 : 1.29 | 1 : 1.24 | |
| Tractive force/Heating surface | 1 : 11.59 | 1 : 13.40 | |
| Grate area/Heating surface | 1 : 72.00 | 1 : 66.24 | |
| Firebox/Tube surface | 1 : 12.68 | 1 : 11.62 | |
| Total/Superheater | 1 : 2.35 | 1 : 2.37 | |