Banner
Navigation

Navigation

loco-info.com
The reference for locomotives and railcars

Great Northern (US) class P-1

United States 1914 15 produced
No. 1755 on a works photo Ron Ziel, „American Locomotives 1858 to 1949” PD

The Great Northern was one of the first railroads in the United States to order Mountain locomotives. The manufacturer Lima saw these as Mikados, which had a two-axle forward bogie for better running characteristics in passenger service. The Great Northern wanted to use the P-1 to eliminate the need for helpers on passenger trains in Montana and the Cascades.

They had a conical boiler with a Belpaire firebox. The first ten P-1s were coal-fired and the last five were oil-fired. The diameter of the drivers was only 62 inches or 1,575 mm, which was an advantage on the steep lines. The speed of passenger trains was now 20 mph (32 km/h) on the 1.8 percent in Montana and 15 mph (24 km/h) on the 2.2 percent in the Cascades, both without helpers.

When these locomotives were no longer sufficient to meet the increased requirements, in 1928 all P-1s were rebuilt into 2-10-2 freight locomotives and designated class Q-2. The drivers and the cylinder diameter were each increased by one inch. The boiler only remained the same on the outside and had many changes on the inside, as well as a higher pressure. They were all coal-fired, but nine were converted to oil in the 1940s. Their decommissioning began in the 1950s and was completed in April 1958.

Technical data

General

Property P-1 rebuilt Q-2
Built 1914 1928
Manufacturers Lima St. Paul
Wheel arrangement 4-8-2 (Mountain) 2-10-2 (Santa Fé)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property P-1 rebuilt Q-2
Wheelbase 11.58 m 9.55 m
Total wheelbase 21.74 m 25.46 m
Service mass 147.9 t 165.1 t
Adhesion mass 98.9 t 131.5 t
Total mass 220.9 t 308.3 t
Rigid wheelbase 5.11 m 6.71 m
Axle load 24.9 t 26.3 t
Water capacity 30,283 l 64,352 l
Fuel capacity 13.6 t (coal) 21,955 l (oil)

Boiler

Property P-1 rebuilt Q-2
Grate area 7.246 m²
Firebox surface 31.587 m² 33.631 m²
Tube heating surface 390.193 m² 414.627 m²
Evaporative heating surface 421.78 m² 448.258 m²
Superheater surface 90.581 m² 109.997 m²
Total heating surface 512.4 m² 558.3 m²

Power plant

Property P-1 rebuilt Q-2
Driver diameter 1,575 mm 1,600 mm
Boiler pressure 12.4 bar 14.5 bar
Expansion type simple expansion
Cylinders two, 711 x 813 mm two, 737 x 813 mm

Power

Property P-1 rebuilt Q-2
Power source steam
Estimated power 2,461 kW (3,346 PS) 2,796 kW (3,802 PS)
Starting effort 275.4 kN 339.2 kN

Calculated values

Property P-1 rebuilt Q-2
Factor of adhesion 1 : 3.52 1 : 3.80
Optimal speed 55 km/h 50 km/h
Power-to-weight ratio 16.6 kW/t 16.9 kW/t
Heating Surface Equivalent 760.9 m² 836.4 m²
Cylinder volume/HSE 1 : 848.74 1 : 828.23
Adhesive weight/Total 1 : 1.50 1 : 1.26
Tractive force/Heating surface 1 : 11.23 1 : 12.69
Grate area/Heating surface 1 : 70.71 1 : 77.04
Firebox/Tube surface 1 : 12.35 1 : 12.33
Total/Superheater 1 : 4.66 1 : 4.08
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.