Banner
Navigation
loco-info.com
The reference for locomotives and railcars

Atlantic Coast Line class R-1

United States 1938 12 produced

In 1938, the Atlantic Coast Line had Baldwin build twelve 4-8-4 Class R-1 locomotives, also known as Class 1800 because of their numbers, for express service between Richmond, Virginia and Jacksonville, Florida. Their design was considered very successful and the boiler in particular exceeded many expectations. They hauled 1,500-ton trains of 20 cars and were even able to accelerate them significantly faster than the manufacturer had initially calculated.

Of note, the direct heating area of the actual firebox was increased from 272 square feet to 568 square feet using a combustion chamber and thermic syphons. The back pressure of the cylinders was also very low, especially in the upper speed range, and allowed greater power output. The only known problem concerned the mass balancing, which was initially calculated incorrectly by Baldwin and still had to be improved.

After the adjustments to the mass balancing, the locomotives were approved for 90 mph and are said to have regularly reached 100 mph. When they later had to haul express freight trains, the maximum train load was rated at 6,200 tons. Their service ended between 1951 and 1952.

Technical data

General

Built
1938
Manufacturers
Baldwin
Wheel arrangement
4-8-4 (Northern)
Gauge
1,435 mm (Standard gauge)

Dimensions and weights

Wheelbase
14.55 m
Total wheelbase
29.85 m
Service mass
208.8 t
Adhesion mass
119.4 t
Total mass
406.1 t
Rigid wheelbase
6.33 m
Axle load
29.8 t
Water capacity
90,850 l
Fuel capacity
24.5 t (coal)

Boiler

Grate area
9.081 m²
Firebox surface
52.769 m²
Tube heating surface
388.8 m²
Evaporative heating surface
441.569 m²
Superheater surface
132.387 m²
Total heating surface
574.0 m²

Power plant

Driver diameter
2,032 mm
Boiler pressure
19 bar
Expansion type
simple expansion
Cylinders
two, 686 x 762 mm

Power

Power source
steam
Estimated power
4,027 kW (5,475 PS)
Top speed
145 km/h
Starting effort
284.2 kN

Calculated values

Factor of adhesion
1 : 4.12
Optimal speed
87 km/h
Power-to-weight ratio
19.3 kW/t
Heating Surface Equivalent
970.2 m²
Cylinder volume/HSE
1 : 580.25
Adhesive weight/Total
1 : 1.75
Tractive force/Heating surface
1 : 10.34
Grate area/Heating surface
1 : 63.20
Firebox/Tube surface
1 : 7.37
Total/Superheater
1 : 3.34
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies