Banner
Navigation

Navigation

loco-info.com
The reference for locomotives and railcars

Baltimore & Ohio class E-27

United States 1905 409 produced
E-27b No. 2899 in front of two Mikados of the Q-1aa class in December 1942 at Chillicothe, Ohio James Bowie / collection Taylor Rush

The largest class of Consolidations built for the Baltimore & Ohio was the E-27. The intended area of service were heavy freight trains on both flat and mountainous routes. In order to keep the strain on the locomotive and tracks low, a driver diameter was chosen that was larger than on previous consolidations and at the same time a long cylinder stroke of 30 inches with a comparatively small diameter.

205 of the original E-27 were built in 1905 and 1906 at the ALCO plants in Schenectady and Richmond. The E-27b only followed in 1909 and was largely the same. Changes only affected the Walschaert valve gear and two-inch larger wheels. After 84 E-27b had been built, 120 more followed, which had a larger number of thinner diameter tubes in the boiler and were given the same designation.

When being superheated, different variants were created, which were given different class names. The differences here lay in the superheater, the cylinder dimensions and the valve gear. A total of 116 E-27 were rebuilt into class L-2 0-8-0 switchers. The last E-27 were retired in 1959.

Technical data

General

Property E-27 E-27b - 1909 E-27b - 1910 rebuilt E-27ca. da
Built 1905-1906 1909-1910 1910 ab 1920
Manufacturers ALCO B&O
Wheel arrangement 2-8-0 (Consolidation)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property E-27 E-27b - 1909 E-27b - 1910 rebuilt E-27ca. da
Wheelbase 7.80 m
Total wheelbase 18.19 m
Service mass 94.6 t 100 t 99.9 t 102.8 t
Adhesion mass 84.3 t 90.1 t 88.7 t 92.3 t
Total mass 159.7 t 167.1 t 169.9 t
Rigid wheelbase 5.08 m
Axle load 21.1 t 22.5 t 22.2 t 24.4 t
Water capacity 26,498 l 28,391 l 26,498 l
Fuel capacity 13.6 t (coal) 16.3 t (coal)

Boiler

Property E-27 E-27b - 1909 E-27b - 1910 rebuilt E-27ca. da
Grate area 5.225 m² 5.3 m² 5.225 m²
Firebox surface 16.658 m²
Tube heating surface 244.307 m² 241.056 m² 247.931 m² 205.66 m²
Evaporative heating surface 260.965 m² 257.713 m² 264.588 m² 222.317 m²
Total heating surface 261.0 m² 257.7 m² 264.6 m² 261.8 m²
Superheater surface 39.484 m²

Power plant

Property E-27 E-27b - 1909 E-27b - 1910 rebuilt E-27ca. da
Driver diameter 1,524 mm 1,575 mm
Boiler pressure 14.1 bar 14.8 bar
Expansion type simple expansion
Cylinders two, 559 x 762 mm two, 610 x 762 mm

Power

Property E-27 E-27b - 1909 E-27b - 1910 rebuilt E-27ca. da
Power source steam
Estimated power 1,230 kW (1,672 PS) 1,249 kW (1,698 PS) 1,454 kW (1,977 PS)
Starting effort 187.6 kN 181.5 kN 226.6 kN

Calculated values

Property E-27 E-27b - 1909 E-27b - 1910 rebuilt E-27ca. da
Factor of adhesion 1 : 4.41 1 : 4.87 1 : 4.79 1 : 4.00
Optimal speed 40 km/h 42 km/h 39 km/h
Power-to-weight ratio 13.0 kW/t 12.3 kW/t 12.5 kW/t 14.1 kW/t
Heating Surface Equivalent 344.3 m² 341.0 m² 347.9 m² 384.6 m²
Cylinder volume/HSE 1 : 1,085.69 1 : 1,096.04 1 : 1,074.38 1 : 1,156.60
Adhesive weight/Total 1 : 1.12 1 : 1.11 1 : 1.13 1 : 1.11
Tractive force/Heating surface 1 : 15.01 1 : 14.71 1 : 14.33 1 : 18.07
Grate area/Heating surface 1 : 49.95 1 : 48.63 1 : 49.92 1 : 50.11
Firebox/Tube surface 1 : 14.67 1 : 14.47 1 : 14.88 1 : 12.35
Total/Superheater 1 : 5.63
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.