Banner
Navigation
loco-info.com
The reference for locomotives and railcars

Philadelphia & Reading class P-3

United States 1900 7 produced
P-3c No. 326 in 1907 at Philadelphia Donald A. Somerville / collection Taylor Rush

In 1900, Baldwin built six Atlantics for the Philadelphia & Reading which were numbered 322 to 327 and designated class P-3a. Built for firing anthracite, they were designed as Camelbacks with a wide Wootten firebox and cab on top of the boiler in front of the firebox. The grate measured 80.7 square feet and the firebox was made even bigger with a combustion chamber that was 48 inches long. These locomotives were Vauclain compounds with cylinder diameters of 15 and 25 inches.

In 1903 they were simpled with cylinders of 21 inches and the boiler pressure was raised from 200 to 220 psi, creating class P-3c. When it was found out that the large number of small tubes did not deliver very good results, they were rebuilt again in 1913 with fewer tubes of increased diameter. They were retired in 1933.

Another locomotive that was originally designated class P-3b was No. 329. It was another Vauclain compound built in 1902 as a comparison to the class P-4a No. 328 with two simple cylinders. Also in this case the two-cylinder variant was better and so 329 received the same cylinders as 328. Now it was also designated class P-4a. Both became class P-4d in 1914 and 1915 when they received new boilers. Also these were retired in 1933.

Technical data

General

Property P-3a rebuilt P-3c rebuilt P-3d P-3b
Built 1900 1903 1914 1902
Manufacturers Baldwin Reading
Wheel arrangement 4-4-2 (Atlantic)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property P-3a rebuilt P-3c rebuilt P-3d P-3b
Wheelbase 8.10 m
Service mass 74.4 t 80.2 t 84.3 t 87.4 t
Adhesion mass 38.1 t 45.6 t 45.1 t 48.9 t
Total mass 128.8 t 156.4 t
Rigid wheelbase 2.21 m
Axle load 19.1 t 22.8 t 22.5 t 25 t
Water capacity 22,523 l 26,498 l
Fuel capacity 7.3 t (coal) 10.9 t (coal)
Length loco 12.22 m 12.48 m

Boiler

Property P-3a rebuilt P-3c rebuilt P-3d P-3b
Grate area 7.497 m² 7.367 m²
Firebox surface 20.847 m² 20.346 m² 16.908 m²
Tube heating surface 215.219 m² 216.557 m² 151.618 m² 256.598 m²
Evaporative heating surface 236.067 m² 236.903 m² 171.964 m² 273.507 m²
Total heating surface 236.1 m² 236.9 m² 172.0 m² 273.5 m²

Power plant

Property P-3a rebuilt P-3c rebuilt P-3d P-3b
Driver diameter 2,140 mm
Boiler pressure 13.8 bar 15.2 bar 13.8 bar
Expansion type compound simple expansion compound
Cylinders four, HP: 381 x 610 mm and LP: 635 x 610 mm two, 533 x 610 mm four, HP: 381 x 610 mm and LP: 635 x 610 mm

Power

Property P-3a rebuilt P-3c rebuilt P-3d P-3b
Power source steam
Estimated power 1,193 kW (1,622 PS) 1,268 kW (1,724 PS) 1,193 kW (1,622 PS) 1,230 kW (1,672 PS)
Starting effort 71.3 kN 104.5 kN 71.3 kN
Starting effort simple 85.5 kN 85.5 kN

Calculated values

Property P-3a rebuilt P-3c rebuilt P-3d P-3b
Factor of adhesion 1 : 5.24 1 : 4.28 1 : 4.23 1 : 6.73
Optimal speed 103 km/h 74 km/h 69 km/h 106 km/h
Power-to-weight ratio 16.0 kW/t 15.8 kW/t 14.2 kW/t 14.1 kW/t
Heating Surface Equivalent 340.3 m² 338.6 m² 273.7 m² 358.0 m²
Cylinder volume/HSE 1 : 975.77 1 : 804.53 1 : 995.42 1 : 927.41
Adhesive weight/Total 1 : 1.95 1 : 1.76 1 : 1.87 1 : 1.79
Tractive force/Heating surface 1 : 6.31 1 : 9.21 1 : 12.69 1 : 5.44
Grate area/Heating surface 1 : 31.49 1 : 31.60 1 : 22.94 1 : 37.13
Firebox/Tube surface 1 : 10.32 1 : 10.64 1 : 7.45 1 : 15.18
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.