Banner
Navigation
loco-info.com
The reference for locomotives and railcars

Canadian National class T-1

Canada 1916 45 produced
T-1-a No. 2002 Taylor Rush collection

In 1916, the Canadian Government Railway received the first ten 2-10-2 locomotives from ALCO-Brooks which soon became Canadian National class T-1-a. Ten more followed in 1918 from Montreal Locomotive Works, these became T-1-b. These locomotives looked relatively short and had their firebox mounted above the last driving axle. This resulted in a low axle load of only 31,000 pounds on the trailing axle, while the leading one carried 33,000 pounds. The five driving axles carried 256,000 pounds, what was an average of more than 51,000 per axle. The drivers had a diameter of 57 inches and the cylinders measured 26 inches in diameter and 32 inches in stroke. In 1920, MLW built 25 more which had a slightly smaller boiler and were lighter. These were put into service as class T-1-c. Some years later, all sub classes received thermic syphons while they lost 19 small tubes. In the thirties, they were rebuilt with completely new boilers. These had a smaller tube heating surface, but the grate area had been increased from 66.7 to 77.3 square feet. The coal capacity of the tenders was increased from 16 to 18 tons with hoppers. The last ones were retired in 1962.

Technical data

General

Property as built rebuilt thermic syphons reboilered
Built 1916-1920
Manufacturers ALCO, Montreal Locomotive Works CNR
Wheel arrangement 2-10-2 (Santa Fé)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property as built rebuilt thermic syphons reboilered
Length 24.75 m
Wheelbase 11.53 m
Total wheelbase 21.41 m
Empty mass 130.6 t
Service mass 145.2 t 144.7 t
Adhesion mass 116.1 t 116.8 t
Total mass 228.2 t 234.8 t
Rigid wheelbase 6.25 m
Water capacity 29,905 l 34,069 l
Fuel capacity 14.5 t (coal) 16.3 t (coal)

Boiler

Property as built rebuilt thermic syphons reboilered
Grate area 6.197 m² 7.181 m²
Firebox surface 26.57 m² 32.609 m²
Tube heating surface 317.078 m² 300.635 m² 278.616 m²
Evaporative heating surface 343.649 m² 333.244 m² 311.225 m²
Superheater surface 78.968 m²
Total heating surface 422.6 m² 412.2 m² 390.2 m²

Power plant

Property as built rebuilt thermic syphons reboilered
Driver diameter 1,448 mm
Boiler pressure 13.8 bar
Expansion type simple expansion
Cylinders two, 660 x 813 mm

Power

Property as built rebuilt thermic syphons reboilered
Power source steam
Estimated power 2,163 kW (2,941 PS) 2,312 kW (3,143 PS) 2,349 kW (3,194 PS)
Starting effort 287.0 kN

Calculated values

Property as built rebuilt thermic syphons reboilered
Factor of adhesion 1 : 3.97 1 : 3.99
Optimal speed 47 km/h 50 km/h
Power-to-weight ratio 14.9 kW/t 15.9 kW/t 16.2 kW/t
Heating Surface Equivalent 634.4 m² 654.2 m² 632.2 m²
Cylinder volume/HSE 1 : 877.67 1 : 851.12 1 : 880.76
Adhesive weight/Total 1 : 1.25 1 : 1.24
Tractive force/Heating surface 1 : 14.18 1 : 14.54 1 : 15.36
Grate area/Heating surface 1 : 68.20 1 : 66.52 1 : 54.34
Firebox/Tube surface 1 : 11.93 1 : 9.22 1 : 8.54
Total/Superheater 1 : 4.35 1 : 4.22 1 : 3.94
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.