Central RR of New Jersey classes G-1s to G-4s and classes P-43, P-47 and P-52

United States 1918 21 produced
No. 833 in December 1937 at Atlantic City, New Jersey Theodore A. Gay / collection Taylor Rush

The Pacifics of the Central Railroad of New Jersey were loosely based on the Reading class G1, so they had a Wootten firebox. The first classes consisted of six G-1s built in 1918 and five G-2s from 1923. Like the later classes, they had been built by Baldwin.

When the CNJ got access to more soft coal, five G-3s were built in 1927. These had a narrower firebox with a width of eight instead of nine feet. Other improvements included a stoker, a mechanic lubricator, a feedwater heater and a larger tender. Five G-4s followed in 1930 which had smaller drivers and a smaller loading gauge for working through the tunnels in eastern Pennsylvania.

In 1945, the CNJ adopted a new class scheme. They now got the prefix P for “Pacific” and a number that denoted the tractive effort in thousands of pounds. So the G-1s and G-2s became the P-43, the G-3s became the P-47 and the G-4s became the P-52. The last ones were retired in 1955.

Technical data

General

Property G-1s G-2s G-3s G-4s
Built 1918 1923 1927 1930
Manufacturers Baldwin
Wheel arrangement 4-6-2 (Pacific)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property G-1s G-2s G-3s G-4s
Wheelbase 10.85 m 11.13 m 11.18 m 11.20 m
Total wheelbase 21.95 m 22.00 m 23.84 m
Service mass 138.9 t 138.8 t 148.1 t 151.4 t
Adhesion mass 81.8 t 88.9 t 89.7 t 93.4 t
Total mass 215.6 t 215.5 t 246.5 t 266.6 t
Rigid wheelbase 4.22 m
Axle load 27.3 t 29 t 29.9 t 31.1 t
Water capacity 30,283 l 37,854 l 51,103 l
Fuel capacity 13.6 t (coal) 10.9 t (coal) 13.6 t (coal)

Boiler

Property G-1s G-2s G-3s G-4s
Grate area 8.808 m² 7.832 m²
Firebox surface 28.15 m² 28.902 m² 37.626 m² 37.254 m²
Tube heating surface 320.887 m² 320.414 m² 319.958 m² 296.361 m²
Evaporative heating surface 349.037 m² 349.316 m² 357.584 m² 333.615 m²
Superheater surface 75.809 m² 73.486 m² 92.903 m²
Total heating surface 424.8 m² 422.8 m² 431.1 m² 426.5 m²

Power plant

Property G-1s G-2s G-3s G-4s
Driver diameter 2,007 mm 1,880 mm
Boiler pressure 14.5 bar 15.9 bar 16.5 bar
Expansion type simple expansion
Cylinders two, 660 x 711 mm

Power

Property G-1s G-2s G-3s G-4s
Power source steam
Estimated power 2,610 kW (3,549 PS) 2,685 kW (3,651 PS) 2,908 kW (3,954 PS)
Starting effort 190.2 kN 208.4 kN 232.1 kN

Calculated values

Property G-1s G-2s G-3s G-4s
Factor of adhesion 1 : 4.22 1 : 4.58 1 : 4.22 1 : 3.95
Optimal speed 84 km/h 79 km/h 77 km/h
Power-to-weight ratio 18.8 kW/t 18.1 kW/t 19.2 kW/t
Heating Surface Equivalent 641.4 m² 640.8 m² 692.7 m² 705.7 m²
Cylinder volume/HSE 1 : 759.61 1 : 760.33 1 : 703.38 1 : 690.42
Adhesive weight/Total 1 : 1.70 1 : 1.56 1 : 1.65 1 : 1.62
Tractive force/Heating surface 1 : 9.35 1 : 9.40 1 : 10.10 1 : 11.37
Grate area/Heating surface 1 : 48.23 1 : 48.00 1 : 55.04 1 : 54.46
Firebox/Tube surface 1 : 11.40 1 : 11.09 1 : 8.50 1 : 7.96
Total/Superheater 1 : 4.60 1 : 4.75 1 : 4.87 1 : 3.59