Banner
Navigation
loco-info.com
The reference for locomotives and railcars

Württemberg Fz

German Reichsbahn class 973

Germany 1893 9 produced
Die Lokomotive, December 1905

The Fz was a 2-6-0 locomotive for use on Riggenbach rack lines. They had two cylinders for adhesion service and two for rack sections. When all cylinders were used together, they could either be used in compound mode or all with high pressure steam. The first four locomotives were built for the line between Honau and Lichtenstein and the next five for the Murgtalbahn between Freudenstadt and Klosterreichenbach. The second batch had two domes which were interconnected with a tube.

They had lots of pulling power on the rack lines, but the boiler was not powerful enough to sustain its pressure on long climbs. So they sometimes had to stop to build up steam again. The Reichsbahn took over seven and numbered them 97 301 to 97 307. Their withdrawals came already in 1930, most likely due to the complicated valve gear.

Schematic drawing Die Lokomotive, December 1905

Technical data

General

Built
1893-1904
Manufacturers
Esslingen
Wheel arrangement
2-6-0RT (Mogul)
Gauge
1,435 mm (Standard gauge)

Dimensions and weights

Length
9.49 m
Wheelbase
5.60 m
Empty mass
43.7 t
Service mass
54.1 t
Adhesion mass
42 t
Rigid wheelbase
3.22 m
Axle load
14 t
Water capacity
4,000 l
Fuel capacity
1.2 t (coal)

Boiler

Grate area
1.394 m²
Firebox surface
7.029 m²
Tube heating surface
115.65 m²
Evaporative heating surface
122.679 m²
Total heating surface
122.7 m²

Power plant

Driver diameter
1,230 mm
Boiler pressure
14 bar
Expansion type
compound
Cylinders
four, HP: 420 x 612 mm and LP: 420 x 540 mm

Power

Power source
steam
Estimated power
350 kW (476 PS)
Top speed
50 km/h
Starting effort
150.2 kN
Starting effort simple
180.3 kN

Calculated values

Factor of adhesion
1 : 2.74
Optimal speed
23 km/h
Power-to-weight ratio
6.5 kW/t
Heating Surface Equivalent
157.8 m²
Cylinder volume/HSE
1 : 1,548.51
Adhesive weight/Total
1 : 1.29
Tractive force/Heating surface
1 : 25.57
Grate area/Heating surface
1 : 88.01
Firebox/Tube surface
1 : 16.45
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.