Buenos Aires Great Southern classes 6, 6A and 6B
In 1888 Beyer, Peacock & Co. built eight 4-4-0 locomotives for the Buenos Aires Great Southern. Two of these were built as Worsdell-von Borries cross-compounds to compare them with the six simple locomotives. The simple ones became class 6 and the compound ones became class 6A. In service it turned out that maintenance of the compound variant was not more complicated compared to the simple variant, while consumption of water and coal was less. In the result of the comparison, Robert Gould wrote that simple engines were only better in shunting service and local traffic. This was especially true for railways without many steep inclines like this one.
This meant that further locomotives were also to be built as compounds. These were designated class 6B and 22 were completed in 1890, also by Beyer Peacock. These featured a larger boiler and cylinder diameters which had been increased by one inch. Before production started, the design of the automatic valve had to be altered. The original design tended to produce sluggish jerks when it switched from simple to compound mode too early.
Technical data
General
| Property | 6 | 6A | 6B |
|---|---|---|---|
| Built | 1888 | 1890 | |
| Manufacturers | Beyer, Peacock & Co. | ||
| Wheel arrangement | 4-4-0 (American) | ||
| Gauge | 1,676 mm (Indian broad gauge) | ||
Dimensions and weights
| Property | 6 | 6A | 6B |
|---|---|---|---|
| Wheelbase | 6.25 m | ||
| Total wheelbase | 11.96 m | ||
| Service mass | 39.2 t | 41.2 t | 42.2 t |
| Adhesion mass | 22.9 t | 23.9 t | 24.4 t |
| Total mass | 64.9 t | 66.9 t | 67.8 t |
| Rigid wheelbase | 2.31 m | ||
| Axle load | 11.5 t | 12 t | 12.4 t |
| Water capacity | 9,093 l | ||
| Fuel capacity | 3 t (coal) | ||
Boiler
| Property | 6 | 6A | 6B |
|---|---|---|---|
| Grate area | 0.875 m² | 0.945 m² | |
| Firebox surface | 7.99 m² | 8.64 m² | |
| Tube heating surface | 78.317 m² | 91.881 m² | |
| Evaporative heating surface | 86.307 m² | 100.521 m² | |
| Total heating surface | 86.3 m² | 100.5 m² | |
Power plant
| Property | 6 | 6A | 6B |
|---|---|---|---|
| Driver diameter | 1,727 mm | ||
| Boiler pressure | 9.7 bar | ||
| Expansion type | simple expansion | compound | |
| Cylinders | two, 406 x 610 mm | two, HP: 406 x 610 mm and LP: 591 x 610 mm | two, HP: 432 x 610 mm and LP: 622 x 610 mm |
Power
| Property | 6 | 6A | 6B |
|---|---|---|---|
| Power source | steam | ||
| Estimated power | 205 kW (279 PS) | 224 kW (305 PS) | |
| Starting effort | 47.8 kN | 32.5 kN | 36.4 kN |
| Starting effort simple | 39.0 kN | 43.7 kN | |
Calculated values
| Property | 6 | 6A | 6B |
|---|---|---|---|
| Factor of adhesion | 1 : 4.69 | 1 : 7.22 | 1 : 6.56 |
| Optimal speed | 26 km/h | 39 km/h | 37 km/h |
| Power-to-weight ratio | 5.2 kW/t | 5.0 kW/t | 5.3 kW/t |
| Heating Surface Equivalent | 126.3 m² | 143.7 m² | |
| Cylinder volume/HSE | 1 : 1,252.61 | 1 : 1,287.55 | 1 : 1,266.16 |
| Adhesive weight/Total | 1 : 1.72 | 1 : 1.73 | |
| Tractive force/Heating surface | 1 : 11.57 | 1 : 7.85 | 1 : 7.57 |
| Grate area/Heating surface | 1 : 98.64 | 1 : 106.37 | |
| Firebox/Tube surface | 1 : 9.80 | 1 : 10.63 | |